2-conductor fuse terminal block

9.45

2-conductor fuse terminal block; with pivoting fuse holder; with additional jumper position; for 5 x 20 mm miniature metric fuse; with blown fuse indication by LED; 12 – 30 V; for DIN-rail 35 x 15 and 35 x 7.5; 2.5 mm²; Push-in CAGE CLAMP®; 2,50 mm²; gray

Compare
SKU: 2002-1911/1000-541 Category:

Description

Electrical data
Fuse receptacle pivoting
Fuse type Cylindrical fuse; 5 x 20 mm
Ratings per IEC/EN
Ratings per IEC/EN 60947-7-3
Ratings (note) Electrical ratings are given by the fuse and blown fuse indication.
Nominal voltage (III/3) 250V
Rated impulse voltage (III/3) 6kV
Rated current 6.3A
Note (rated current) Leakage current in case of a blown fuse: LED 2 mA
Operation status indicator 12 … 30 V
Legend (ratings) (III / 3) ≙ Overvoltage category III / Pollution degree 3
Ratings per UL
Approvals per UL 1059
Rated voltage UL (Use Group B) 30V
Rated current UL (Use Group B) 6.3A
Rated voltage UL (Use Group C) 30V
Rated current UL (Use Group C) 6.3A
Rated voltage UL (Use Group D) 30V
Rated current UL (Use Group D) 6.3A
Ratings per CSA
Approvals per CSA 22.2 No 158
Rated voltage CSA (Use Group B) 250V
Rated current CSA (Use Group B) 6.3A
Rated voltage CSA (Use Group C) 250V
Rated current CSA (Use Group C) 6.3A
Ex information
Reference hazardous areas See Downloads – Documentation – Additional Information: Technical Section; Technical explanations
Ratings per ATEX: KIWA 17 ATEX 0030 U / IECEx: KIWA 17.0014U (Ex ec IIC Gc)
Rated voltage EN (Ex e II) 24V
Rated current (Ex e II) 6.3A
Power loss
Power loss (max.) Pl (max.) (note) When selecting glass cartridge fuses, make sure that the maximum power loss listed below is not exceeded. The power loss is determined according to IEC or EN 60947-7-3/VDE 0611-6 at 23°C. The temperature rise of the terminal block must be checked according to their application and mounting. Higher ambient temperatures represent an additional impact on miniature fuses. Therefore, in such applications, the rated current must be reduced if necessary. More details are available from the manufacturers.
Power loss Pl max. overload and short-circuit protection (individual arrangement) 1.6W
Power loss Pl max. overload and short-circuit protection (group arrangement) 1.6W
Power loss Pl max. short-circuit protection (individual arrangement) 2.5W
Power loss Pl max. short-circuit protection (group arrangement) 2.5W
Connection data
Total number of connection points 2
Total number of potentials 1
Number of levels 1
Number of jumper slots 3
Connection 1
Connection technology Push-in CAGE CLAMP®
Actuation type Operating tool
Connectable conductor materials Copper
Nominal cross-section 2.5 mm²
Solid conductor 0.25 … 4 mm² / 22 … 12 AWG
Solid conductor; push-in termination 0.75 … 4 mm² / 18 … 12 AWG
Fine-stranded conductor 0.25 … 4 mm² / 22 … 12 AWG
Fine-stranded conductor; with insulated ferrule 0.25 … 2.5 mm² / 22 … 14 AWG
Fine-stranded conductor; with ferrule; push-in termination 1 … 2.5 mm² / 18 … 14 AWG
Note (conductor cross-section) Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length 10 … 12 mm / 0.39 … 0.47 inches
Wiring direction Front-entry wiring